Optional controls must be factory installed. Field installation is not

acceptable and violates Listing and factory warranty.

Degree F air rise is measured at 1,000 F.P.M. and 600 CFM. Throw

designed for 8 to 12 foot ceilings. db RE 10

-12

Watt=63.9

Unit Weight:

50 lbs.

Low Voltage:

UT1001

• White powder coated 20 gauge grill.

• All units have manual reset thermal limit, 24V control

transformer, and 24V relay (A1 suffix).

• Enclosed steel fin sheath element.

• Rough in dimensions: 23-1/16” sq. x 9-1/8” deep.

• Made in U.S.A.

Notes

Standard Models

Product Dimensions

Product Specifications

Features

Factory Installed Control Sections

Contractor shall supply and install heavy duty ceiling mounted

forced air electric heater(s) of the wattage, voltage and phase as

indicated on the plans. The heater shall be so designed to provide an

even distribution of heated air to the space to be heated by drawing

return air in the periphery of the heater, across and through the

element and be discharged from the center section of the heater by

means of an electric motor and axial flow fan blade.

Heaters shall be recessed type and mounted flush with the finished

ceiling. The return grille assembly shall be constructed of a one

piece heavy gauge steel with 1/4” slots for return air and concentric

rings for uniform air discharge. Grille assembly shall be attached to

chassis by tamper-resistant (allen head) machine screws. All parts

of enclosure shall be heavy gauge steel, zinc coated both sides and

finished in neutral off white powder coat paint.

Enclosure shall be constructed of 1/6” x 3/8” rounded edge

horizontal steel louvers which shall be spaced for maximum opening

of 5/16”. Louvers shall be welded at every intersection to evenly

spaced 1/8” diameter vertical members. Discharge grille to have

concentric rings for uniform air discharge. Grille assembly shall be

attached to chassis by tamper-resistant (allen head) machine screws.

All part of enclosure shall be heavy gauge steel, Zinc coated both

sides and finished in neutral off white colored powder coat finish.

Motor shall be permanent lubricated, unit bearing, totally

enclosed, impedance protection. Motors shall operate at no more

than 1300 RPM and shall be same voltage as the heater.

Heaters shall have a rating of 600 CFM at 1,000 F.P.M. with a

maximum temperature rise of 44°F and 63.9 DB RE 10 12 Watt.

Element assemblies shall consist of two or three corrosion

resistant steel sheathed type elements mechanically bonded to

common corrosion resistant steel fins. Each sheathed element shall

consist of helically coiled Nickel Chromium alloy resistant wire

completely embedded in and surrounded by magnesium oxide,

enclosed and wedged into corrosion resistant steel sheaths. Elements

shall have 2” cold conductor pins extending into sheath and shall

have a density of no more than 60 Watts per inch.

Heaters shall be equipped with a “manual reset” thermal overload

which disconnects elements and motor in the event normal operating

temperatures are exceeded. For safety, if opened due to abnormal

temperature, thermal overload shall remain open until manually

reset. Automatic reset thermal overloads which allow the element

to continue to cycle under abnormal conditions will not be accepted.

Heaters shall be ETL listed.

SUFFIX

DESCRIPTION

S

Disconnect Switch

T

Thermostat

RELAYS FOR FIELD SUPPLIED CONTROL - NIGHTLY SETBACK

R

Relay Control Voltage Same as Heater (control voltage field supplied)

R1

Relay 24V Control Voltage (control voltage field supplied)

R2

Relay 120V Control Voltage (control voltage field supplied)

RCH Series Commercial Fan Forced Recessed Mounted Ceiling Heater

MFG

CATALOG

NUMBER

MFG

MODEL

NUMBER

KW BTU’S VOLTS PH AMPS TEMP

RISE

03153302 81RCH2A1

2 6826

208

1

9.6

15 °F

03152602 21RCH2A1

240

8.3

03149702 71RCH2A1

277

7.2

03184702 41RCH2A1

480

4.2

04702802 83RCH2A1

2 6826

208

3

5.6

15 °F

03984902 23RCH2A1

240

4.8

04702402 43RCH2A1

480

2.4

03153202 81RCH3A1

3

10200

208

1

14.4

22 °F

03148402 21RCH3A1

240

12.5

03148102 71RCH3A1

277

10.8

03184802 41RCH3A1

480

6.3

04706402 83RCH3A1

3

208

3

8.3

03985002 23RCH3A1

240

7.2

04702502 43RCHA1

480

3.6

03153602 81RCH4A1

4

13600

208

1

19.2

30 °F

03155402 21RCH4A1

240

16.8

03148002 71RCH4A1

277

14.4

03185002 41RCH4A1

480

8.3

03148702 83RCH4A1

4

208

3

11.1

03148202 23RCH4A1

240

9.7

03185802 43RCH4A1

480

4.8

03154802 81RCH5A1

5

17000

208

1

24.1

37 °F

03155102 21RCH5A1

240

20.8

03149602 71RCH5A1

277

18.1

03185402 41RCH5A1

480

10.4

03150802 83RCH5A1

5

208

3

13.9

03180902 23RCH5A1

240

12.1

03184002 43RCH5A1

480

6.1

03661002

PT3480

Recess Frame - Weight 5 lbs.

International Models

04709702 M3482T2i

2 6826

220

1

9.1 15 °F

04709802 N3482T2i

240

8.3

04709902 M3483T2i

3 10200 220

13.6 22 °F

04710002 N3483T2i

240

12.5

04710102 M3484T2i

4 13600 220

18.2 30 °F

04710202 N3484T2i

240

16.7