65
B
A
C
ICP Control Panels
Housing & Construction:
.040 Gold anodized Aluminum housing for efficient, long-term
reflectivity and corrosion resistance. High-density radiant heat.
Housing is ETL Listed for indoor, dry environment applications
only. Made in U.S.A.
Reflector:
60 degree symmetric heat pattern, reference the sizing chart to
determine overall coverage based on the mounting height.
Elements:
Heavy duty flat panel emitter. Available wattages in 1450, 3150,
4300 and 9500 Watts per element. Available in standard voltages
from 120 to 600 Volts.
Controls:
Flat panel emitter heaters are not manufactured with any control
device on the unit. All controls and accessories should be
specified as remote mounted. Please consult the technical sales
department of factory for help in determining applicable controls.
Please follow installation instructions that accompany each
heater.
Accessories:
Power contactor panels.
FSS-95
Product Specifications
Mounting Clearances & Recommended Mounting Height
FSS Series Dimensions
Sizing Chart
Mounting Clearances
KW Recommended Mounting Height
All FSS Models
24” from ceiling
36” from vertical surface & from another heater
72” from face of heater to combustible surface
1.4
8’ - 10’
3.1
8’ - 12’
4.3
10’ - 14’
9.5
12’ - 16’
FSS-95 Tandem Only
87” from face of heater to combustible surface
(2) 9.5
15’ - 30’
FSS Series Heavy Duty Flat Panel Emitter Electric Overhead Infrared Heater
(2) FSS-95 heaters with TMK-95 tandem mounting kit
MOUNTING
HEIGHT
MFG
MODEL
NUMBER
LENGTH WIDTH COVERAGE
(SQ. FT.)
WATTS
(SQ. FT.)
8’
FSS-14
8
8
64
22.7
FSS-31
9
8
72
43.8
10’
FSS-14
11
10
110
13.2
FSS-31
11
10
110
28.6
FSS-43
12
10
120
35.8
12’
FSS-31
12
11.5
138
22.8
FSS-43
14
12
168
25.6
FSS-95
15
13
195
48.7
14’
FSS-43
16
14
224
19.2
FSS-95
18
16
288
33.0
16’
FSS-43
18
16
288
14.9
FSS-95
21
18
378
25.1
FSS-95
TANDEM 24
19
456
41.7
18’
FSS-95
23
20
460
20.7
FSS-95
TANDEM 28
20
560
33.9
20’
FSS-95
TANDEM 28
23
644
29.5
24’
FSS-95
TANDEM 33
27
891
21.3
30’
FSS-95
TANDEM 41
32
1312
14.5
• NEMA 4 outdoor rated control box
• Door interlock disconnect switch
• Custom made to customers specifications
• SCR and proportional controls optional
• Circuit reakers sized for heater load per stage
• Please see ICP page to select panel to
control one or multiple units, if required.
Features
MFG
MODEL
NUMBER
DIMENSIONS (in.)
“A”
DEPTH
“B”
WIDTH
“C”
LENGTH
FSS-14
8-1/2
9
26
FSS-31
8-1/2
9
46
FSS-43
9-3/4
20
29
FSS-95
7-3/4
20
49
FSS-95 TANDEM 7-3/4
20
108