Table of Contents Table of Contents
Previous Page  65 / 117 Next Page
Information
Show Menu
Previous Page 65 / 117 Next Page
Page Background

65

B

A

C

ICP Control Panels

Housing & Construction:

.040 Gold anodized Aluminum housing for efficient, long-term

reflectivity and corrosion resistance. High-density radiant heat.

Housing is ETL Listed for indoor, dry environment applications

only. Made in U.S.A.

Reflector:

60 degree symmetric heat pattern, reference the sizing chart to

determine overall coverage based on the mounting height.

Elements:

Heavy duty flat panel emitter. Available wattages in 1450, 3150,

4300 and 9500 Watts per element. Available in standard voltages

from 120 to 600 Volts.

Controls:

Flat panel emitter heaters are not manufactured with any control

device on the unit. All controls and accessories should be

specified as remote mounted. Please consult the technical sales

department of factory for help in determining applicable controls.

Please follow installation instructions that accompany each

heater.

Accessories:

Power contactor panels.

FSS-95

Product Specifications

Mounting Clearances & Recommended Mounting Height

FSS Series Dimensions

Sizing Chart

Mounting Clearances

KW Recommended Mounting Height

All FSS Models

24” from ceiling

36” from vertical surface & from another heater

72” from face of heater to combustible surface

1.4

8’ - 10’

3.1

8’ - 12’

4.3

10’ - 14’

9.5

12’ - 16’

FSS-95 Tandem Only

87” from face of heater to combustible surface

(2) 9.5

15’ - 30’

FSS Series Heavy Duty Flat Panel Emitter Electric Overhead Infrared Heater

(2) FSS-95 heaters with TMK-95 tandem mounting kit

MOUNTING

HEIGHT

MFG

MODEL

NUMBER

LENGTH WIDTH COVERAGE

(SQ. FT.)

WATTS

(SQ. FT.)

8’

FSS-14

8

8

64

22.7

FSS-31

9

8

72

43.8

10’

FSS-14

11

10

110

13.2

FSS-31

11

10

110

28.6

FSS-43

12

10

120

35.8

12’

FSS-31

12

11.5

138

22.8

FSS-43

14

12

168

25.6

FSS-95

15

13

195

48.7

14’

FSS-43

16

14

224

19.2

FSS-95

18

16

288

33.0

16’

FSS-43

18

16

288

14.9

FSS-95

21

18

378

25.1

FSS-95

TANDEM 24

19

456

41.7

18’

FSS-95

23

20

460

20.7

FSS-95

TANDEM 28

20

560

33.9

20’

FSS-95

TANDEM 28

23

644

29.5

24’

FSS-95

TANDEM 33

27

891

21.3

30’

FSS-95

TANDEM 41

32

1312

14.5

• NEMA 4 outdoor rated control box

• Door interlock disconnect switch

• Custom made to customers specifications

• SCR and proportional controls optional

• Circuit reakers sized for heater load per stage

• Please see ICP page to select panel to

control one or multiple units, if required.

Features

MFG

MODEL

NUMBER

DIMENSIONS (in.)

“A”

DEPTH

“B”

WIDTH

“C”

LENGTH

FSS-14

8-1/2

9

26

FSS-31

8-1/2

9

46

FSS-43

9-3/4

20

29

FSS-95

7-3/4

20

49

FSS-95 TANDEM 7-3/4

20

108

3/4” K.O. ON FSS-43,-95

1/2” K.O. ON FSS-14, -31