Field Installed Accessories

HOW TO DESIGNATE AMODEL:

E

93

96 B 250 3 ITS PD

Heater Length

(inches)

28, 36, 48, 60,

72, 84, 96, 108,

or 120

Inlet

B = Bottom

F = Front

Element Volts

F = 208

H = 240

G = 277

L = 347

P1 = 480

U1 = 600

Single Phase

J = 208

K = 240

P3 = 480

U3 = 600

Three Phase

Watts Per Foot

Per Element

100, 125, 150,

165, 187, 200,

or 250

Control Options

Refer to Pg. 60

of TPI Heat

catalog.

Factory Installed

Accessories

PD = Pedestal

DR = Receptacle

WM = Screen

Model Series

93

# of Elements

1, 2, or 3

9300 Series - Radius Front Draft Barrier Heater

• LEED and green compliance, 1 and 3 phase applications

• Industrial or commercial applications

• Standard color: Bankers Bronze (powder coated)

• Also available in other standard TPI colors and custom colors

for an additional charge

• Uni-lock construction for snap fit 2 piece installation

• Temperature control can be in-built or wall mounted

• Thermal protection by full length manual reset linear limits

• Optional accessories include: duplex receptacle, and inside or

outside corner sections for wall to wall custom fit.

• Additional charges may be incurred if changes are made after

production has begun - consult factory.

• Made in U.S.A.

Features

ETL listed up to 750 Watts

/ foot for industrial or

commercial applications.

Note: All models are suitable for International use

Product Description

Factory Installed Accessories

Standard Models

TECHNICAL INFORMATION

Height

7.5”

Depth

6.15”

Length

28” to 120” in 1’ increments

Cabinet Material

Material Gauge

Aluminum

12

Optional Controls That

Can Be Built Into Unit

Thermostat, Disconnect Switch, Transformer

(Control Section Required for Relays)

TECHNICAL INFORMATION

Air Intake

Bottom / Front

Air Discharge

Top

Min Mounting Height

3” for bottom intake / 0” for front intake

Max Watts / Foot

750

Max Allowable Amps

25 without relay, 40 with relay

Voltage / Phase

208V/240V/277V/347V,480V,600V Single Phase

208V,240V,480V,600V Three Phase

Note: If using line voltage thermostat on 1 phase heaters, you

cannot exceed 25 Amps due to Amp rating of thermostat. 347,

480, and 600V can use 30 Amps with in-built thermostat.

Note: 480V single phase units minimum 36” heated length; 600V single phase units minimum 48” heated length

347-480-600 single phase and all three phase units are built with low voltage option factory installed

Note: Extended enclosure per foot is 103 dollars.

MFG

MODEL

UNIT

LENGTH

LIST FINISHED

BACK ADDER

Heater

9328 28”

824

65

9336 36”

867

72

9348 48”

977

77

9360 60”

1085

82

9372 72”

1164

87

9384 84”

1246

93

9396 96”

1314

98

93108 108”

1378

103

93120 120”

1467

109

SUFFIX

DESCRIPTION

LIST

DR Duplex Receptacle in 4” Extended

Enclosure (not available with 120” heater)

151

PD

28” through 60” - 2 Required

151

72” through 96” - 3 Required

228

108” through 120” - 4 Required

301

WM 1/4” wire mesh under grill

$6.00

Per

foot

IDS30

30 Amp/240V Disconnect Switch

77

IDS40

40 Amp/600V Disconnect Switch

77

MFG

MODEL

DESCRIPTION

LIST

9300IC Inside Corner Section 90° or 135°

243

9300OC Outside Corner Section 90° or 135°

9300EC

Right or Left End Cap

93

MFG

MODEL

UNIT

LENGTH

LIST FINISHED

BACK ADDER

Blank Section

93BS012 12”

338

60

93BS024 24”

397

65

93BS036 36”

445

72

93BS048 48”

515

77

93BS060 60”

576

82

93BS072 72”

623

87

93BS084 84”

683

93

93BS096 96”

743

98

93BS108 108”

803

103

93BS120 120”

862