75
Electric Infrared Heating Controls
Pre-Wired Contactor Panels
FPC2120
Factory pre-wired for quick installation,
with the following optional equipment:
Snow & Ice Detector (APS-3C)
Single & Two-Stage Thermostats
Two-stage thermostats require a
minimum 2-contactors.
Note: Contact factory for 3R, 4, 4X, & NEMA 12 “special” built models.
Step-down transformer and secondary
fusing for 24V or 120V control circuit.
3-Phase load rated.
Fuses are NOT included.
NEMA 1 Enclosures.
Max 50-Amp branch circuit fusing.
IMPORTANT FUSING INFORMATION
Fuses are NOT included since panels can be used with various infrared heat sources. Quartz
Lamp Heat Sources: Use FRS-600V (or equal) “Time Delay” fuses; Class RK-5. Quartz Tube
& metal Sheath Heat Sources: Use KTS-R 600V (or equal) “Fast Acting” fuses; Class RK-1.
Fuse circuits as close to calculated load as possible. Circuits less than 35 Amps will require the
use of fuse reducers.
Manufactured in U.S.A.
Standard Models
120-V CONTROL SYSTEM 24-V CONTROL SYSTEM
MAX
AMPS
VOLTS
CABINET SIZE (IN.)
WT.
(LBS.)
UPC# 686334
MODEL UPC# 686334
MODEL
DEPTH WIDTH HEIGHT
4459902
FPC8110
4864302
FPC8210
50
208
6.75
16
24
52
4460002
FPC2110
4864402
FPC2210
240
4460102
FPC7110
4864502
FPC7210
277/480
4460202
FPC4110
4864602
FPC4210
480
4460302
FPC8120
4864702
FPC8220
100
208
6.75
16
24
70
4460402
FPC2120
4864802
FPC2220
240
4460502
FPC7120
4864902
FPC7220
277/480
4460602
FPC4120
4865002
FPC4220
480
4460702
FPC8140
4865102
FPC8240
200
208
6.75
24
30
88
4460802
FPC2140
4865202
FPC2240
240
4460902
FPC7140
4865302
FPC7240
277/480
4461002
FPC4140
4865402
FPC4240
480
4461102
FPC8160
4865502
FPC8260
300
208
6.75
30
36
106
4461202
FPC2160
4865602
FPC2260
240
4461302
FPC7160
4865702
FPC7260
277/480
4461402
FPC4160
4865802
FPC4260
480